Product
M2-1M
14 mm digit height
TypeM2-1M
Housing96 x 48
Display5-digit
14 mm digit height
Color: red
Optional: green, orange or blue display
Range displayed-19999 to 99999
Operationfront panel keyboard
InputDMS / Mass pressure 1 mV - 3.3 mV
Analogue output-
Switch point250 VAC / 2 AAC ; 30 VDC / 2 ADC
Interface-
Sensor supplyFeeding 10 VDC / 20 mA incl. digital input
Comment
  • Minimal installation depth: 70 mm (without plug-in terminal)
  • Option: 2 relay outputs (Change-over contacts)
Data sheet
Print version
To top
Product
M3-1M
14 mm digit height
TypeM3-1M
Housing96 x 48
Display5-digit
14 mm digit height
Color: red
Optional: green, orange or blue display
Range displayed-19999 to 99999
Operationfront panel keyboard
InputDMS / Mass pressure 1 mV - 3.3 mV
Analogue output0/4...20 mA
0...10 V
16 bit switchable
Switch point250 VAC / 2 AAC ; 30 VDC / 2 ADC
InterfaceRS232
RS422
(galvanic insulated)
Sensor supplyFeeding 10 VDC / 20 mA incl. digital input
Comment
  • Minimal installation depth: 120 mm (without plug-in terminal)
  • Option: 1 or 2 analog outputs or 4 relay outputs (change-over contacts)
  • Option: 2 or 4 relay outputs (change-over contacts)
  • Option: 8 PhotoMos outputs
Data sheet
Print version
To top
Product
PM5
14 mm digit height
TypePM5
Housing96 x 48
Display5-digit
7-segment-display
14 mm digit height
Range displayed-9999...99999
Operationfront panel keyboard / with tare function
Inputstrain gauge:|1 mV/V|2 mV/V|3,3 mV/V
Analogue output0...10 V
0...20 mA
4...20 mA
Switch point4 relay outputs
InterfaceRS232
RS485
Sensor supplyBridge supply 10 V / 50 mA for 350 Ohm measuring bridge
Comment
  • mass pressure/weighing technology in 4-wire measuring
  • swith contact for automatic 80% calibration
Manual
Data sheet
Print version
To top
Product
PME4 AUSLAUFMODELL - PHASED-OUT MODEL !!!
14 mm digit height
TypePME4 AUSLAUFMODELL - PHASED-OUT MODEL !!!
Housing96 x 48
Display4-digit
7-segment-display
14 mm digit height
Range displayed-999...9999
Operationfront panel keyboard / with calibration function
InputDMS sensitivity 1 mV/V
DMS sensitivity 2 mV/V
DMS sensitivity 3 mV/V
Analogue output0...20 mA
4...20 mA
0...10 V
Switch point2 relay outputs
Sensor supplyBridge supply 10 V / 50 mA
CommentDirect measuring of melt pressure sensors and automatic offset-/80% calibration.
Manual
Data sheet
Print version
To top