Montwill GmbH EN Panel meter Strain gauge / weighing technology 96 x 48 mm 
		
					
						
										
						
				
Technical Data
| Housing | 96 x 48 mm | 
| Display | 5-digit 14 mm digit height
 Colour: red, green, orange or blue display
 | 
| Range displayed | -19999 to 99999 | 
| Operation | front panel keyboard protection class IP65 | 
| Input | DMS / Weighing technology: 1 mV/V, 2 mV/V, 3.3 mV/V free to 4 mV/V Digital input: <2.4V OFF, >10V ON, max. 30 VDC
 | 
| Analogue Output | – | 
| Switch point | 2 relays (change-over contact) 250 V / 5 AAC, 30 V / 5 ADC
 | 
| Interface | – | 
| Power supply | 230 VAC 10-30 VDC galvanic isolated
 Other voltage supplies on demand!
 | 
| Sensor supply | Bbridge feeding 10 VDC / 2-40 mA / 300-5000 Ohm | 
| Software properties | 
min/max-memory with adjustable permanent display30 additional adjustable supporting pointsdisplay flashing at threshold value exceedance/undercutzero-key for triggering of Hold, Tara or setpoint settingstandard digital input for triggering of Hold, Tara or setpoint settingflexible alarm system with adjustable delay timesmathematical functions like reciprocal value, square root, squaring and roundingsliding averagingbrightness control via parameter or front keysprogramming interlock via access code | 
| Downloads | Data sheet and price list Manual
 | 
 
| Housing | 96 x 48 mm | 
| Display | 5-digit 14 mm digit height
 Colour: red, green, orange or blue display
 | 
| Range displayed | -19999 to 99999 | 
| Operation | front panel keyboard protection class IP65 | 
| Input | DMS / Weighing technology: 1mV/V, 2 mV/V, 3.3 mV/V free to 4 mV/V Digital input: <2.4V OFF, >10V ON, max. 30 VDC
 | 
| Analogue Output | 2 analog outputs 0/4-20 mA / 0-10 VDC / 16 Bit
 | 
| Switch point | 2 or 4 relays (change-over contacts) 250 V / 5 AAC, 30 V / 5 ADC
 or 8 PhotoMos outputs (NOC) 30 V / 0.4 A AC/DC
 | 
| Interface | RS232 or RS485 galvanic isolated Alternatively to analog output 2
 | 
| Power supply | 100-240 VAC 50/60 Hz / DC +/- 10% 10-40 VDC / 18-30 VAC 50/60Hz
 | 
| Sensor supply | Bbridge feeding 10 VDC / 2-40 mA / 300-5000 Ohm | 
| Software properties | 
min/max-memory with adjustable permanent display30 additional adjustable supporting pointsdisplay flashing at threshold value exceedance/undercutzero-key for triggering of Hold, Tara or setpoint settingstandard digital input for triggering of Hold, Tara or setpoint settingflexible alarm system with adjustable delay timesmathematical functions like reciprocal value, square root, squaring and roundingsliding averagingbrightness control via parameter or front keysprogramming interlock via access code | 
| Downloads | Data sheet and price list Manual
 | 
 
| Housing | 96 x 48 mm | 
| Display | 5-digit 14 mm digit height
 Colour: red
 | 
| Range displayed | -9999…99999 | 
| Operation | front panel keyboard protection class IP65 | 
| Input | Strain gauge / Weighing technology: 1mV/V, 2 mV/V, 3,3 mV/V frei bis 6 mV/V Digital input: <2.4V OFF, >10V ON, max. 30 VDC
 | 
| Analogue Output | 0-20 mA Burden ≤500Ohm 12Bit 4-20 mA Burden ≤500Ohm 12Bit
 0-10 VDC Burden ≥100kOhm 12Bit
 | 
| Switch point | 2 or 4 relays (change-over contacts) 250 V / 5 AAC, 30 V / 5 ADC
 | 
| Interface | RS232 or RS485 galvanic isolated | 
| Power supply | 100-240 VAC 50/60 Hz / DC +/- 10% 10-40 VDC / 18-30 VAC 50/60Hz
 | 
| Sensor supply | Bridge supply 10 VDC / 20-50 mA / 200-500 Ohm | 
| Software properties | 
integrated factory calibration for preset weighing cellsfree selectable scaling and decimal point adjustmentalignment of a sensor with up to 30 additional supporting pointstaring function for manual and automated triggeringfully automated or semi-automatic functionsmin/max-memory with adjustable permanent displaydisplay flashing at threshold value exceedance/undercutflexible alarm system with adjustable delay timeprogramming interlock via access code | 
| Downloads | Data sheet and price list Manual
 |